Pulse Oximetry Performance in Darkly Pigmented Skin: Methodological Concerns. Anesth Analg. 2024 Oct 11.
Sharma V, Barker SJ, Novak J, Wilson WC. PMID: 39392777.
View in:
PubMed Mentions: Fields:
-
Response to 'Randomised crossover study on pulse oximeter readings from different sensors in very preterm infants' by Maiwald et al. Arch Dis Child Fetal Neonatal Ed. 2024 May 30.
Sharma V, Barker SJ, Sola A, Cantillon D, Sorci R, Wilson WC. PMID: 38816191.
View in:
PubMed Mentions: Fields:
-
Racial effects on masimo pulse oximetry: impact of low perfusion index. J Clin Monit Comput. 2024 Apr; 38(2):347-354.
Sharma V, Barker SJ, Sorci R, Park L, Wilson WC. PMID: 38238634; PMCID: PMC10995008.
View in:
PubMed Mentions:
3 Fields:
Translation:
Humans
-
Racial effects on Masimo pulse oximetry: a laboratory study. J Clin Monit Comput. 2023 04; 37(2):567-574.
Barker SJ, Wilson WC. PMID: 36370242; PMCID: PMC9652601.
View in:
PubMed Mentions:
12 Fields:
Translation:
Humans
-
Correspondence to: performance of the new SmartCardia wireless, wearable oximeter: a comparison with arterial SaO2 in healthy volunteers. BMC Anesthesiol. 2022 09 26; 22(1):303.
Barker SJ, Wilson WC. PMID: 36163005; PMCID: PMC9511712.
View in:
PubMed Mentions:
1 Fields:
Translation:
Humans
-
Pro-Con Debate: Should Code Sharing Be Mandatory for Publication? Anesth Analg. 2022 08 01; 135(2):241-245.
Melvin RL, Barker SJ, Kiani J, Berkowitz DE. PMID: 35839495.
View in:
PubMed Mentions: Fields:
-
Continuous Noninvasive Hemoglobin Monitoring: A Measured Response to a Critical Review. Anesth Analg. 2016 Feb; 122(2):565-72.
Barker SJ, Shander A, Ramsay MA. PMID: 25746056; PMCID: PMC4708068.
View in:
PubMed Mentions:
23 Fields:
Translation:
Humans
-
Disclosures, What Is Necessary and Sufficient? Anesth Analg. 2016 Feb; 122(2):307-8.
Shelley KH, Barker SJ. PMID: 26797547.
View in:
PubMed Mentions:
2 Fields:
Translation:
Humans
-
In Response. Anesth Analg. 2015 Dec; 121(6):1680-2.
Prielipp RC, Morell RC, Coursin DB, Brull SJ, Barker SJ, Rice MJ, Vender JS, Cohen NH. PMID: 26579669.
View in:
PubMed Mentions: Fields:
Translation:
Humans
-
The Future of Anesthesiology: Should the Perioperative Surgical Home Redefine Us? Anesth Analg. 2015 May; 120(5):1142-1148.
Prielipp RC, Morell RC, Coursin DB, Brull SJ, Barker SJ, Rice MJ, Vender JS, Cohen NH. PMID: 25867643.
View in:
PubMed Mentions:
4 Fields:
Translation:
Humans
-
Dialogue on the Future of Anesthesiology. Anesth Analg. 2015 May; 120(5):1152-1154.
Prielipp RC, Morell RC, Coursin DB, Brull SJ, Barker SJ, Rice MJ, Vender JS, Cohen NH, Warner MA, Apfelbaum JL. PMID: 25899276.
View in:
PubMed Mentions: Fields:
Translation:
Humans
-
Practice advisory for the prevention and management of operating room fires: an updated report by the American Society of Anesthesiologists Task Force on Operating Room Fires. Anesthesiology. 2013 Feb; 118(2):271-90.
Apfelbaum JL, Caplan RA, Barker SJ, Connis RT, Cowles C, Ehrenwerth J, Nickinovich DG, Pritchard D, Roberson DW, Caplan RA, Barker SJ, Connis RT, Cowles C, de Richemond AL, Ehrenwerth J, Nickinovich DG, Pritchard D, Roberson DW, Wolf GL, American Society of Anesthesiologists Task Force on Operating Room Fires. PMID: 23287706.
View in:
PubMed Mentions:
23 Fields:
Translation:
Humans
-
New sensors should improve Masimo SpMet error found by Feiner et al. Anesth Analg. 2010 Jul; 111(1):241; author reply 241.
Barker SJ. PMID: 20576969.
View in:
PubMed Mentions: Fields:
Translation:
Humans
-
Electrical safety in the operating room: dry versus wet. Anesth Analg. 2010 Jun 01; 110(6):1517-8.
Barker SJ, Doyle DJ. PMID: 20501809.
View in:
PubMed Mentions:
2 Fields:
Translation:
Humans
-
Severe methemoglobinemia detected by pulse oximetry. Anesth Analg. 2009 Mar; 108(3):898-9.
Annabi EH, Barker SJ. PMID: 19224799.
View in:
PubMed Mentions:
10 Fields:
Translation:
Humans
-
The measurement of dyshemoglobins and total hemoglobin by pulse oximetry. Curr Opin Anaesthesiol. 2008 Dec; 21(6):805-10.
Barker SJ, Badal JJ. PMID: 18997533.
View in:
PubMed Mentions:
20 Fields:
Translation:
HumansAnimals
-
Practice advisory for the prevention and management of operating room fires. Anesthesiology. 2008 May; 108(5):786-801; quiz 971-2.
American Society of Anesthesiologists Task Force on Operating Room Fires, Caplan RA, Barker SJ, Connis RT, Cowles C, de Richemond AL, Ehrenwerth J, Nickinovich DG, Pritchard D, Roberson D, Wolf GL. PMID: 18431114.
View in:
PubMed Mentions:
14 Fields:
Translation:
Humans
-
Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study. Anesthesiology. 2006 Nov; 105(5):892-7.
Barker SJ, Curry J, Redford D, Morgan S. PMID: 17065881.
View in:
PubMed Mentions:
44 Fields:
Translation:
Humans
-
Problems with forehead reflectance pulse oximetry. Respir Care. 2006 Jul; 51(7):715-6.
Barker SJ. PMID: 16800901.
View in:
PubMed Mentions:
1 Fields:
Translation:
Humans
-
Faculty and finances of United States anesthesiology training programs: 2002-2003. Anesth Analg. 2004 Oct; 99(4):1185-1192.
Tremper KK, Shanks A, Sliwinski M, Barker SJ, Hines R, Tait AR. PMID: 15385373.
View in:
PubMed Mentions:
3 Fields:
Translation:
Humans
-
Too much technology? Anesth Analg. 2003 Oct; 97(4):938-939.
Barker SJ. PMID: 14500136.
View in:
PubMed Mentions: Fields:
Translation:
Humans
-
A demographic, service, and financial survey of anesthesia training programs in the United States. Anesth Analg. 2003 May; 96(5):1432-1446.
Tremper KK, Barker SJ, Gelman S, Reves JG, Saubermann AJ, Shanks AM, Greenfield MLVH, Anderson ST. PMID: 12707147.
View in:
PubMed Mentions:
1 Fields:
Translation:
Humans
-
Organizational factors affect comparisons of the clinical productivity of academic anesthesiology departments. Anesth Analg. 2003 Mar; 96(3):802-812.
Abouleish AE, Prough DS, Barker SJ, Whitten CW, Uchida T, Apfelbaum JL. PMID: 12598266.
View in:
PubMed Mentions:
1 Fields:
-
"Motion-resistant" pulse oximetry: a comparison of new and old models. Anesth Analg. 2002 Oct; 95(4):967-72, table of contents.
Barker SJ. PMID: 12351278.
View in:
PubMed Mentions:
30 Fields:
Translation:
HumansCTClinical Trials
-
Standardization of the testing of pulse oximeter performance. Anesth Analg. 2002 Jan; 94(1 Suppl):S17-20.
Barker SJ. PMID: 11900031.
View in:
PubMed Mentions: Fields:
Translation:
Humans
-
Fire in the operating room: a case report and laboratory study. Anesth Analg. 2001 Oct; 93(4):960-5.
Barker SJ, Polson JS. PMID: 11574364.
View in:
PubMed Mentions:
13 Fields:
Translation:
Humans
-
Pulse oximeter performance during desaturation and resaturation: a comparison of seven models. J Clin Anesth. 1997 May; 9(3):184-8.
Trivedi NS, Ghouri AF, Lai E, Shah NK, Barker SJ. PMID: 9172023.
View in:
PubMed Mentions:
10 Fields:
Translation:
HumansCTClinical Trials
-
Effects of motion, ambient light, and hypoperfusion on pulse oximeter function. J Clin Anesth. 1997 May; 9(3):179-83.
Trivedi NS, Ghouri AF, Shah NK, Lai E, Barker SJ. PMID: 9172022.
View in:
PubMed Mentions:
26 Fields:
Translation:
HumansCTClinical Trials
-
The effects of motion on the performance of pulse oximeters in volunteers (revised publication). Anesthesiology. 1997 Jan; 86(1):101-8.
Barker SJ, Shah NK. PMID: 9009945.
View in:
PubMed Mentions:
26 Fields:
Translation:
Humans
-
Incidence of perioperative myocardial ischemia in TURP patients. J Clin Anesth. 1996 Dec; 8(8):627-30.
Wong DH, Hagar JM, Mootz J, Christiano M, Vora SH, Miller JB, Barker SJ. PMID: 8982888.
View in:
PubMed Mentions:
3 Fields:
Translation:
Humans
-
Effects of motion on the performance of pulse oximeters in volunteers. Anesthesiology. 1996 Oct; 85(4):774-81.
Barker SJ, Shah NK. PMID: 8873547.
View in:
PubMed Mentions:
7 Fields:
Translation:
Humans
-
Measurement of pulmonary CO2 elimination must exclude inspired CO2 measured at the capnometer sampling site. J Clin Monit. 1996 May; 12(3):231-6.
Breen PH, Serina ER, Barker SJ. PMID: 8823647.
View in:
PubMed Mentions:
5 Fields:
Translation:
Humans
-
Exhaled flow monitoring can detect bronchial flap-valve obstruction in a mechanical lung model. Anesth Analg. 1995 Aug; 81(2):292-6.
Breen PH, Serina ER, Barker SJ. PMID: 7618717.
View in:
PubMed Mentions:
5 Fields:
Translation:
Humans
-
Factors associated with postoperative pulmonary complications in patients with severe chronic obstructive pulmonary disease. Anesth Analg. 1995 Feb; 80(2):276-84.
Wong DH, Weber EC, Schell MJ, Wong AB, Anderson CT, Barker SJ. PMID: 7818113.
View in:
PubMed Mentions:
32 Fields:
Translation:
Humans
-
Cerebral metabolism during propofol anesthesia in humans studied with positron emission tomography. Anesthesiology. 1995 Feb; 82(2):393-403; discussion 27A.
Alkire MT, Haier RJ, Barker SJ, Shah NK, Wu JC, Kao YJ. PMID: 7856898.
View in:
PubMed Mentions:
78 Fields:
Translation:
HumansAnimals
-
Anesthesia workstation for 2010. J Clin Monit. 1994 Sep; 10(5):304-5.
Barker SJ. PMID: 7983479.
View in:
PubMed Mentions:
1 Fields:
Translation:
Humans
-
Experimental and predicted dual oximetry variability. J Clin Monit. 1993 Sep; 9(4):268-74.
Wong DH, Weir P, Mahutte CK, Onishi R, Daves S, Foran W, Ferraro L, Barker SJ. PMID: 8301334.
View in:
PubMed Mentions: Fields:
-
A comparison of bag mask and mouth mask ventilation in anaesthetised patients. Resuscitation. 1993 Aug; 26(1):13-21.
Thomas AN, O'Sullivan K, Hyatt J, Barker SJ. PMID: 8210726.
View in:
PubMed Mentions: Fields:
Translation:
Humans
-
The effect of sensor malpositioning on pulse oximeter accuracy during hypoxemia. Anesthesiology. 1993 Aug; 79(2):248-54.
Barker SJ, Hyatt J, Shah NK, Kao YJ. PMID: 8342837.
View in:
PubMed Mentions:
4 Fields:
Translation:
Humans
-
Anesthesia for thoracoscopic laser ablation of bullous emphysema. Anesthesiology. 1993 Jan; 78(1):44-50.
Barker SJ, Clarke C, Trivedi N, Hyatt J, Fynes M, Roessler P. PMID: 8424570.
View in:
PubMed Mentions:
2 Fields:
Translation:
Humans
-
The Laerdal pocket mask: effects of increasing supplementary oxygen flow. Anaesthesia. 1992 Nov; 47(11):967-71.
Thomas AN, Hyatt J, Chen JL, Barker SJ. PMID: 1466439.
View in:
PubMed Mentions: Fields:
Translation:
Humans
-
Hyperventilation reduces transcutaneous oxygen tension and skin blood flow. Anesthesiology. 1991 Oct; 75(4):619-24.
Barker SJ, Hyatt J, Clarke C, Tremper KK. PMID: 1928771.
View in:
PubMed Mentions:
4 Fields:
Translation:
HumansAnimals
-
Continuous blood gas monitoring with an intraarterial optode during one-lung anesthesia. J Cardiothorac Vasc Anesth. 1991 Aug; 5(4):365-7.
Greenblott GB, Tremper KK, Barker SJ, Gerschultz S, Gehrich JL. PMID: 1873515.
View in:
PubMed Mentions:
5 Fields:
Translation:
Humans
-
Continuous measurement of intraarterial pHa, PaCO2, and PaO2 in the operating room. Anesth Analg. 1991 Jul; 73(1):43-8.
Barker SJ, Hyatt J. PMID: 1907111.
View in:
PubMed Mentions:
12 Fields:
Translation:
Humans
-
Effects of anemia on pulse oximetry and continuous mixed venous hemoglobin saturation monitoring in dogs. Anesthesiology. 1991 Jul; 75(1):118-22.
Lee S, Tremper KK, Barker SJ. PMID: 2064035.
View in:
PubMed Mentions:
14 Fields:
Translation:
Animals
-
Thoracoscopic carbon dioxide laser treatment of bullous emphysema. Lancet. 1991 Apr 13; 337(8746):881-3.
Wakabayashi A, Brenner M, Kayaleh RA, Berns MW, Barker SJ, Rice SJ, Tadir Y, Della Bella L, Wilson AF. PMID: 1672970.
View in:
PubMed Mentions:
16 Fields:
Translation:
Humans
-
In vivo tumor oxygen tension measurements for the evaluation of the efficiency of photodynamic therapy. Photochem Photobiol. 1990 Aug; 52(2):375-85.
Tromberg BJ, Orenstein A, Kimel S, Barker SJ, Hyatt J, Nelson JS, Berns MW. PMID: 2145595.
View in:
PubMed Mentions:
22 Fields:
Translation:
Animals
-
Tumor oxygen tension during photodynamic therapy. J Photochem Photobiol B. 1990 Apr 01; 5(1):121-6.
Tromberg BJ, Kimel S, Orenstein A, Barker SJ, Hyatt J, Nelson JS, Roberts WG, Berns MW. PMID: 2140411.
View in:
PubMed Mentions:
5 Fields:
Translation:
Animals
-
Detection of venous air embolism by continuous intraarterial oxygen monitoring. J Clin Monit. 1990 Jan; 6(1):53-6.
Greenblott G, Barker SJ, Tremper KK, Gerschultz S, Gehrich JL. PMID: 2295897.
View in:
PubMed Mentions:
2 Fields:
Translation:
Humans
-
Transcutaneous and liver surface PO2 during hemorrhagic hypotension and treatment with phenylephrine. Crit Care Med. 1989 Jun; 17(6):537-40.
Tremper KK, Barker SJ, Hufstedler SM, Weiss M. PMID: 2498037.
View in:
PubMed Mentions: Fields:
Translation:
Animals
-
The optode: next generation in blood gas measurement. Crit Care Med. 1989 May; 17(5):481-2.
Tremper KK, Barker SJ. PMID: 2707021.
View in:
PubMed Mentions: Fields:
Translation:
Humans
-
Pulse oximetry. Anesthesiology. 1989 Jan; 70(1):98-108.
Tremper KK, Barker SJ. PMID: 2643368.
View in:
PubMed Mentions:
70 Fields:
Translation:
Humans
-
Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry. Anesthesiology. 1989 Jan; 70(1):112-7.
Barker SJ, Tremper KK, Hyatt J. PMID: 2912291.
View in:
PubMed Mentions:
58 Fields:
Translation:
Animals
-
Benzocaine-induced methemoglobinemia in an adult: accuracy of pulse oximetry with methemoglobinemia. Anesth Analg. 1988 Nov; 67(11):1099-101.
Anderson ST, Hajduczek J, Barker SJ. PMID: 3189900.
View in:
PubMed Mentions:
10 Fields:
Translation:
Humans
-
Comparison of three oxygen monitors in detecting endobronchial intubation. J Clin Monit. 1988 Oct; 4(4):240-3.
Barker SJ, Tremper KK, Hyatt J, Heitzmann H. PMID: 3193146.
View in:
PubMed Mentions:
3 Fields:
Translation:
Animals
-
Noninvasive monitoring of carbon dioxide: a comparison of the partial pressure of transcutaneous and end-tidal carbon dioxide with the partial pressure of arterial carbon dioxide. J Clin Monit. 1987 Jul; 3(3):149-54.
Phan CQ, Tremper KK, Lee SE, Barker SJ. PMID: 3612214.
View in:
PubMed Mentions:
14 Fields:
Translation:
Humans
-
The effect of carbon monoxide inhalation on pulse oximetry and transcutaneous PO2. Anesthesiology. 1987 May; 66(5):677-9.
Barker SJ, Tremper KK. PMID: 3578881.
View in:
PubMed Mentions:
40 Fields:
Translation:
Animals
-
Cardiovascular effects of anesthesia and operation. Crit Care Clin. 1987 Apr; 3(2):251-68.
Barker SJ, Gamel DM, Tremper KK. PMID: 3332199.
View in:
PubMed Mentions:
9 Fields:
Translation:
Humans
-
Intra-arterial oxygen tension monitoring. Int Anesthesiol Clin. 1987; 25(3):199-208.
Barker SJ, Tremper KK. PMID: 3323064.
View in:
PubMed Mentions: Fields:
Translation:
Humans
-
Transcutaneous oxygen measurement: experimental studies and adult applications. Int Anesthesiol Clin. 1987; 25(3):67-96.
Tremper KK, Barker SJ. PMID: 3323066.
View in:
PubMed Mentions:
3 Fields:
Translation:
Humans
-
Continuous fiberoptic arterial oxygen tension measurements in dogs. J Clin Monit. 1987 Jan; 3(1):48-52.
Barker SJ, Tremper KK, Hyatt J, Zaccari J, Heitzmann HA, Holman BM, Pike K, Ring LS, Teope M, Thaure TB. PMID: 3819796.
View in:
PubMed Mentions:
8 Fields:
Translation:
Animals
-
Pulse oximetry: applications and limitations. Int Anesthesiol Clin. 1987; 25(3):155-75.
Barker SJ, Tremper KK. PMID: 3323062.
View in:
PubMed Mentions:
15 Fields:
Translation:
Humans
-
Effects of anesthetic agents on the drift of a transcutaneous oxygen tension sensor. J Clin Monit. 1986 Oct; 2(4):234-6.
Tremper KK, Barker SJ, Blatt DH, Wender RH. PMID: 3783195.
View in:
PubMed Mentions:
1 Fields:
Translation:
Humans
-
A clinical comparison of transcutaneous PO2 and pulse oximetry in the operating room. Anesth Analg. 1986 Jul; 65(7):805-8.
Barker SJ, Tremper KK, Gamel DM. PMID: 3717619.
View in:
PubMed Mentions:
8 Fields:
Translation:
Humans
-
Temperature correction of blood gas tensions? Anesth Analg. 1986 Apr; 65(4):420-1.
Anderson ST, Barker SJ. PMID: 3082249.
View in:
PubMed Mentions: Fields:
Translation:
Humans
-
Continuous noninvasive estimation of cardiac output by electrical bioimpedance: an experimental study in dogs. Crit Care Med. 1986 Mar; 14(3):231-3.
Tremper KK, Hufstedler SM, Barker SJ, Zaccari J, Harris D, Anderson S, Roohk V. PMID: 3943340.
View in:
PubMed Mentions:
5 Fields:
Translation:
Animals
-
Relationship of transcutaneous PO2 to arterial PO2. Can Anaesth Soc J. 1986 Jan; 33(1):108-9.
Tremper KK, Anderson S, Barker SJ. PMID: 3948037.
View in:
PubMed Mentions: Fields:
Translation:
Humans
-
Transcutaneous oxygen tension: a physiological variable for monitoring oxygenation. J Clin Monit. 1985 Apr; 1(2):130-4.
Barker SJ, Tremper KK. PMID: 3831253.
View in:
PubMed Mentions:
3 Fields:
Translation:
HumansAnimals